Tuba Installation Guide Technical Specifications
MAN-TUBIG (Ver. 1.502)
www.elmomc.com
69
4.9. Feedbacks
The Tuba can receive and process feedback input from diverse types of devices.
4.9.1. Feedback Supply Voltage
Feature Details
Main encoder supply voltage 5 V +5% @ 200 mA maximum
Auxiliary encoder supply voltage 5 V +5% @ 200 mA maximum
4.9.2. Incremental Encoder Input
Feature Details
Encoder format
• A, B and Index
• Differential
• Quadrature
Interface: RS-422
Input resistance
Differential: 120 Ω
Maximum incremental encoder frequency Maximum: 5 MHz pulses
Minimum quadrature input period (PIN) 112 nsec
Minimum quadrature input high/low period
(P
HL)
56 nsec
Minimum quadrature phase period (PPH) 28 nsec
Maximum encoder input voltage range
Common mode: ±7 V
Differential mode: ±7 V
Figure 34: Encoder Phase Diagram
Kommentare zu diesen Handbüchern