ZX[N] - User Program and Auto-tuning Temporary
Storage
Purpose:
Serves as temporary storage of reference waveforms for the controller in automatic
tuning experiments. Out of the scope of auto-tuning experiments, the ZX[N] vector can
be used as a large temporary storage for user programs.
Notes:
The elements of ZX[N] are short (16-bit) integers.
The ZX[N] command does not check input ranges. Assigning out-of-range values
to ZX[N] can result in unpredictable results.
Attributes: Type: Parameter, Integer
Source: Program, RS-232, CANopen
Restrictions: None
Default value: 0
Range: [-32,768…32,767]
Index range: [0…1023]
Unit modes: All
Activation: Immediate